Air conditioning of the cinema
Kučírek, Pavel ; Jelínek, Ondřej (referee) ; Blasinski, Petr (advisor)
The topic of this bachelor’s thesis is design of three air conditioner units for cinema with technical utility rooms, base for workers and gallery. The devices are designed to meet the operating, hygienic and functional requirements for internal microclimate. The main role of air conditioning devices is air supplying for visitors in sufficient amount, eliminating thermal loads in summer, covering thermal losses and humidification during winter. The theoretical part is focused on internal microclimate.
Energy efficient building of cinema and gallery
Kučírek, Pavel ; Jelínek, Ondřej (referee) ; Blasinski, Petr (advisor)
The aim of the master project is to design a new building of the cinema with gallery and to design technical equipment. The building is „L“ shaped, the half of the building is single-storey and the other half is two-storey, there is no basement. The most important rooms are on the ground floor – gallery, cinema, foyer and staff rooms. On the second floor there is projector room, sound engineer room, recording room and other sound adjusting rooms. The vertical loadbearing and non-loadbearing walls are designed from aerated concrete blocks, horizontal structure are cast-in-place reinforced slabs, the roof is flat. There is a reinforced concrete staircase that leads to the second floor, the building is insulated by ETICS. There are 4 HVAC units designed in the building, units are controlled with monitoring and controlling unit, also there are photovoltaics and rainwater storage systems designed. The project and visualizations were made in the ArchiCAD, MS excel, DEK, Halton HIT, AeroCAD software. Experiment validates measured data with mathematical analytics model that I used in 7 theoretical models of ventilator controlling possibilities to achieve energy savings. Re-sults will be compared and assessed.
Energy efficient building of cinema and gallery
Kučírek, Pavel ; Jelínek, Ondřej (referee) ; Blasinski, Petr (advisor)
The aim of the master project is to design a new building of the cinema with gallery and to design technical equipment. The building is „L“ shaped, the half of the building is single-storey and the other half is two-storey, there is no basement. The most important rooms are on the ground floor – gallery, cinema, foyer and staff rooms. On the second floor there is projector room, sound engineer room, recording room and other sound adjusting rooms. The vertical loadbearing and non-loadbearing walls are designed from aerated concrete blocks, horizontal structure are cast-in-place reinforced slabs, the roof is flat. There is a reinforced concrete staircase that leads to the second floor, the building is insulated by ETICS. There are 4 HVAC units designed in the building, units are controlled with monitoring and controlling unit, also there are photovoltaics and rainwater storage systems designed. The project and visualizations were made in the ArchiCAD, MS excel, DEK, Halton HIT, AeroCAD software. Experiment validates measured data with mathematical analytics model that I used in 7 theoretical models of ventilator controlling possibilities to achieve energy savings. Re-sults will be compared and assessed.
Air conditioning of the cinema
Kučírek, Pavel ; Jelínek, Ondřej (referee) ; Blasinski, Petr (advisor)
The topic of this bachelor’s thesis is design of three air conditioner units for cinema with technical utility rooms, base for workers and gallery. The devices are designed to meet the operating, hygienic and functional requirements for internal microclimate. The main role of air conditioning devices is air supplying for visitors in sufficient amount, eliminating thermal loads in summer, covering thermal losses and humidification during winter. The theoretical part is focused on internal microclimate.

Interested in being notified about new results for this query?
Subscribe to the RSS feed.